CEPROCON.COM • BLOG ARTICLE • WEEK 4
The key document behind every CE marked construction product
The declaration of performance for construction products is the legal backbone of CE marking. If CE marking is the visible sign that a construction product complies with European requirements, the Declaration of Performance — or DoP — is the legal document that stands behind it. Without a valid DoP, the CE mark on a product is meaningless. With a well-prepared one, it is a powerful commercial and regulatory asset.
Yet despite its central importance, the DoP is one of the most commonly misunderstood and poorly prepared documents in the construction products sector. Manufacturers rush it, underestimate it, or copy it from other products without checking whether it is appropriate. The result is documents that create legal exposure rather than legal protection.
This article explains what the DoP is, what it must contain, why it matters legally and commercially, and the most common mistakes to avoid.
What is the Declaration of Performance?
The Declaration of Performance is a formal document that a manufacturer must draw up before affixing the CE mark to a construction product. It is required by Article 4 of the Construction Products Regulation (CPR), Regulation (EU) No 305/2011.
Its purpose is straightforward: to state, in a standardised format, how the product performs against the essential characteristics defined in the applicable harmonised standard or European Assessment Document. In doing so, it provides the common language that allows buyers, specifiers, architects, engineers, and regulators across all EU member states to understand what a product does and how well it does it.
By drawing up and signing a DoP, the manufacturer takes full legal responsibility for the conformity of the product with the declared performance. This is not a trivial commitment. If the product does not perform as declared and causes harm to a building, to people, or to the environment, the DoP is the document that establishes the manufacturer’s accountability.
What must a DoP contain?
The mandatory content of a DoP is set out in Article 6 of the CPR and further detailed in Annex III. There are nine required elements:
| # | Required element | What this means in practice |
| 1 | Unique identification code | A reference code that uniquely identifies the DoP and links it to a specific product type. |
| 2 | Product type | A clear description of the product type, including its intended use and any relevant dimensions, grades, or variants. |
| 3 | Intended use(s) | The use(s) for which the product is intended, as specified in the harmonised technical specification. |
| 4 | Manufacturer’s name and address | The full legal name and registered address of the manufacturer — the party taking legal responsibility. |
| 5 | Authorised representative (if applicable) | If a non-EU manufacturer uses an EU-based authorised representative, their details must be included. |
| 6 | AVCP system | The Assessment and Verification of Constancy of Performance system applied to the product (1+, 1, 2+, 3, or 4). |
| 7 | Harmonised standard or EAD reference | The reference number and date of the harmonised standard or European Assessment Document used. |
| 8 | Notified Body details (if applicable) | Where a Notified Body was involved in the AVCP process, their name, identification number, and the certificate reference must be stated. |
| 9 | Declared performance table | The core of the DoP: a table listing each essential characteristic and the declared performance value (or “Not Determined” / “No Performance Determined” where applicable). |
The performance table: the heart of the DoP
Of all the required elements, the declared performance table deserves the most attention. This is where the manufacturer states, characteristic by characteristic, how the product performs.
For each essential characteristic listed in the harmonised standard, the manufacturer must either:
- Declare a performance level or class (e.g. reaction to fire: Class B-s2,d0; compressive strength: CS(10)I), or
- State “No Performance Determined” (NPD) for characteristics that are not relevant to the product’s intended use in the markets where it will be sold.
The NPD option is widely misunderstood and frequently misused. It does not mean the manufacturer does not know the performance — it means the characteristic is genuinely not relevant to the intended use in the markets where the product will be placed. Using NPD for characteristics that are in fact required by national regulations or building codes in the target market can render the CE marking commercially useless, even if it is technically compliant.
A well-prepared DoP declares performance for all the characteristics that buyers, specifiers, and regulators in the target market will actually need. This requires knowing not just the harmonised standard, but the market context in which the product will be used.
Language, format, and availability requirements
The CPR sets specific requirements for how the DoP must be made available:
Language
The DoP must be provided in the language(s) required by the member state(s) where the product is placed on the market. If a product is sold in France, the DoP must be available in French. If it is sold across five EU countries, it must be available in each of those five languages. A single English-language DoP is not sufficient for markets that require a local language version.
Format
The DoP may be provided on paper or electronically. Since 2013, manufacturers have been permitted to make the DoP available on a website, provided the product is accompanied by instructions explaining how to access it. This is now common practice for manufacturers with large product ranges.
Retention
The manufacturer must keep a copy of the DoP available for ten years after the product has been placed on the market. This is a long retention period that many smaller manufacturers overlook, and it has implications for document management and version control.
The legal and commercial significance of the DoP
The DoP is not administrative paperwork. It is a legal declaration that carries real consequences:
Manufacturer liability
By issuing a DoP, the manufacturer formally declares that the product conforms to the stated performance. If the product fails to perform as declared and damage results — structural failure, fire spread, water ingress, release of harmful substances — the DoP establishes what was claimed and by whom. It is a central document in any product liability claim.
Market access
Distributors, contractors, and public procurement bodies across the EU are increasingly requiring DoPs as part of their supply chain due diligence. A missing, incomplete, or clearly erroneous DoP can result in a product being rejected by a buyer even if it is technically CE marked.
Regulatory enforcement
Market surveillance authorities check DoPs as part of their enforcement activities. A DoP that is incomplete, references the wrong standard, or contains obviously implausible declared values will attract attention. Products can be required to be withdrawn from the market and manufacturers can face fines.
The five most common DoP mistakes
- Using an outdated standard reference. Harmonised standards are revised. A DoP referencing a superseded version of a standard is non-compliant from the date the new version becomes mandatory.
- Copying a DoP from a similar product without adapting it. Every DoP must relate to a specific product type. A DoP prepared for one product cannot simply be reused for a different product, even one that appears similar, without careful review.
- Excessive use of NPD. Declaring “No Performance Determined” for characteristics that buyers in target markets actually need renders the CE marking commercially valueless. Always consider the market context when deciding which characteristics to declare.
- Inconsistency between the DoP and the CE marking label. The CE marking affixed to the product must be consistent with what is declared in the DoP. Discrepancies — different performance classes, missing characteristics — create confusion and potential legal exposure.
- Not updating the DoP when the product changes. If a product’s composition, dimensions, production process, or intended use changes in a way that could affect its performance, the DoP must be reviewed and updated accordingly.
Summary
The Declaration of Performance is the legal foundation of CE marking for construction products. It is the document through which the manufacturer takes responsibility for their product’s performance, communicates that performance to the market, and demonstrates compliance with the CPR.
A well-prepared DoP is an asset. An incomplete, incorrect, or carelessly prepared one is a liability. Given that the CE mark and the DoP are inseparable — one cannot exist without the other — investing the time and expertise to get the DoP right is not optional. It is the point.
Need help preparing or reviewing your Declaration of Performance?
At CEProCon, DoP preparation and review is one of our core services. We help manufacturers get it right the first time — correctly structured, fully compliant, and commercially relevant to their target markets. We also cover DoP preparation in depth in our CE marking training programme.
If you’d like expert help preparing or reviewing your Declaration of Performance, our Technical File & Declaration of Performance Preparation service covers this end to end. And if you want a wider check of your overall CPR compliance, our CPR Compliance Audit & Gap Analysis service can help identify any gaps.
contact@ceprocon.com • ceprocon.com