CE marking for structural products: steel, timber, concrete — key considerations

ceprocon week14 fixed

CEPROCON.COM  •  BLOG ARTICLE  •  WEEK 14

Steel, timber and concrete each sit under their own family of harmonised standards, with different AVCP systems, different Notified Body requirements, and different failure points for manufacturers who assume “CE marking is CE marking.”

Not all construction products play by the same rules — and structural products are where that becomes most obvious. If you’re used to one material family, moving into another can mean re-learning the compliance route almost from scratch, even though the underlying CPR logic stays the same. This article covers CE marking structural products — steel, timber and concrete — and where CEProCon most often sees manufacturers get caught out when expanding into a new structural category.

Why structural products get their own rulebook

Structural products carry the building’s load. If they fail, the consequences aren’t cosmetic — they’re safety-critical. That’s why the harmonised standards covering steel, timber and concrete structural components tend to demand more rigorous verification than, say, decorative finishes or non-structural insulation. In practice, this means higher AVCP systems, more consistent Notified Body involvement, and Factory Production Control (FPC) regimes that go well beyond a basic quality checklist.

But “more rigorous” doesn’t mean “identical.” Each material family has its own harmonised standard, its own declared performance characteristics, and its own AVCP system. Treating them as interchangeable is one of the most common mistakes CEProCon sees among manufacturers expanding into a new product category.

Structural steel: EN 1090-1

Structural steel and aluminium components fall under EN 1090-1, which covers CE marking for structural steelwork — everything from steel beams to welded assemblies used in load-bearing structures. This is one of the more mature harmonised standards in the construction sector, and it comes with a distinctive requirement: manufacturers must hold a valid Factory Production Control certificate issued by a Notified Body before they can CE mark under this standard at all.

EN 1090-1 uses AVCP System 2+ for most structural steel components, which means:

  • The manufacturer determines the product type and carries out type testing.
  • The manufacturer operates ongoing FPC.
  • A Notified Body certifies the FPC system itself — not individual product batches — and carries out surveillance audits, typically annually.

This is a system-level certification, not a product-level one. Once your FPC is certified, you can self-declare performance for new products within scope, provided your FPC continues to cover them. Manufacturers frequently underestimate how much documentation this requires — welding procedure specifications, welder qualifications, and material traceability records all form part of what the Notified Body audits. We cover this in more depth, including the welding certification side, in our structural steel CE marking guide.

Structural timber: a more fragmented picture

Timber structural products don’t sit under one standard the way steel does — they’re split by product type. Solid structural timber is covered by EN 14081-1 (strength-graded structural timber), while glued laminated timber (glulam) falls under EN 14080. Structural insulated panels, roof trusses and other engineered timber products may fall under yet other standards or, where no harmonised standard exists, the EAD/ETA route.

AVCP systems vary accordingly. EN 14081-1 typically applies System 2+ for strength-graded structural timber when machine grading is used, requiring Notified Body certification of the FPC system — similar in principle to structural steel, though the technical content of the audit (grading machine calibration, settings, species and origin control) is entirely different. Visually graded timber can, in some cases, fall under a lighter regime, which is a distinction manufacturers often miss when they switch grading methods without reviewing whether their compliance route needs to change too.

This is also where the EAD/ETA route shows up most often in structural work. If a timber product doesn’t fit neatly under an existing harmonised standard — a proprietary engineered timber system, for example — the manufacturer works with a Technical Assessment Body (TAB) to obtain a European Technical Assessment (ETA). Where the EAD underlying that ETA specifies an AVCP system requiring third-party involvement, a Notified Body still gets involved at the certification stage — separately from the TAB, which only issues the ETA itself. These are two distinct bodies performing two distinct roles, and conflating them is a mistake worth avoiding both in your technical file and in conversations with clients.

Precast and structural concrete products

Concrete is arguably the most fragmented of the three. General rules for precast concrete products are set out in EN 13369, but individual product types — hollow core slabs, concrete blocks, bridge beams, foundation piles — each have their own product-specific harmonised standard that sits on top of it. The AVCP system assigned depends heavily on the specific product and its safety-criticality: many standard precast elements use System 2+ or System 4, while safety-critical items — anchor channels used in structural connections, for instance — are assessed under the more stringent System 1 or 1+, requiring Notified Body product certification rather than just FPC certification.

This spread — from System 4 (no third-party involvement at all) to System 1+ (Notified Body certifies the product itself, including audit-testing of samples) — makes concrete the category where manufacturers most need to check their specific product standard rather than assume. Two products that look similar on a yard can sit under completely different verification regimes, so it’s worth confirming the correct standard and AVCP system before quoting a project timeline to a client.

Where manufacturers most often go wrong

  • Assuming FPC certification and product certification are the same thing. Under System 2+, the Notified Body certifies your FPC system — under System 1/1+, it certifies the product itself. The paperwork, ongoing obligations, and what happens if something changes in your process differ significantly between the two.
  • Missing a grading or process change that shifts the AVCP system. Switching from visual to machine grading in timber, or introducing a new product line in concrete, can move a product into a different system — and a different set of Notified Body obligations — without anyone flagging it.
  • Treating the EAD/ETA route as “no Notified Body needed.” That’s only true if the underlying EAD doesn’t specify third-party involvement. Many do.
  • Reusing a Declaration of Performance template across product families. Steel, timber and concrete DoPs reference different standards, different essential characteristics, and often different AVCP systems — a copy-pasted DoP is one of the fastest ways to end up with a non-compliant declaration.

The common thread

Despite the differences, the underlying logic is consistent across all three materials: the more safety-critical the product’s role in the structure, the higher the AVCP system, and the more direct the Notified Body’s involvement. Once you understand that gradient — and check where your specific product standard sits on it — the rest of the compliance picture becomes much easier to navigate, regardless of which material you’re working with. If you’re not yet confident locating that information yourself, our guide on harmonised standards under the CPR explains how to find and read the standard that applies to your product.